HORIZONTAL BOILER TECHNICAL SPECIFICATION

OPERATING PRESSURE:-  45 p.s.i ~ 3.0 Bar

MAXIMUM PERMISSIBLE PRESSURE: - 60 p.s.i ~ 4.0 Bar

SAFETY VALVE RELIEF PRESSURE: -  60 p.s.i ~ 4.0 Bar

WEIGHT EMPTY INCLUDING FITTINGS: - 1.7 Kilos

INTERNAL VOLUME: 0.7 Litres

LENGTH: - 160 mm

DIAMETER: - 90 mm

The unit is a marine centre flue boiler with cross tubes, internal vertical flu and return tube. The boiler is of all copper construction with the exception of brass fire tube blanking plates and brass funnel location. All bushes and ferules are of bronze. It is designed for gas firing by butane/propane mix. The stand is manufactured from anodised aluminium and stainless steel.

The boiler is supplied with sight glass, steam valve, pressure gauge and ceramic burner. Options include feed water heater, gas attenuator, combined by-pass/check valve, blow down valve, rechargeable gas tank and oil separator.

Share by: